Nailor vav terminal units. Nailor Industries Inc. Nailor vav terminal units

 
Nailor Industries IncNailor vav terminal units  Figure 2: Support Using Unistrut and Rods (Shown: Model 3001Q - Single Duct Figure 3: Support Using Optional Supplied Hanger Brackets (Shown: Model D30RWQ - Single Duct VAV Quiet Terminal Unit with Standard Dissipative The terminal unit is typically located above the ceiling and can serve multiple spaces

D. An SINGLE DUCT TERMINAL UNITS A SINGLE DUCT TERMINAL UNITS • 30X/HQX SERIES Nailor Single Duct Exhaust Terminal Units are used to modulate exhaust flow from an occupied space in either a constant volume or variable air volume (VAV) HVAC system. Nailor Industries Inc. Jerry Jackson for agreeing to serve. Nailor 3200 Series Dual Duct Terminal Units are designed to maintain optimal temperature control in the conditioned zone by varying the air volume supplied by the hot and cold supply ducts while providing proper discharge air temperature. of the sizes and capabilities as indicated on the drawings. Figure 2: Support Using Unistrut and Rods (Shown: Model 3001Q - Single Duct Figure 3: Support Using Optional Supplied Hanger Brackets (Shown: Model D30RWQ - Single Duct VAV Quiet Terminal Unit with Standard Dissipative The terminal unit is typically located above the ceiling and can serve multiple spaces. These. PEFMT 4 445 XJUI 0"* 0VUEPPS "JS *OMFU Minimum Ventilation, Series Flow (Constant Volume) FOR VAV TERMINAL UNITS Nailor Industries Inc. Nailor manufactures a range of standard and custom design retrofit terminal units for all applications. The engineer must also consider how the terminal units are going to be. Catalogs. Single duct, parallel fan-powered, and series fan-powered units are connected to an air handling unit (AHU) that supplies the terminal units with cooled and dehumidified air. SINGLE DUCT TERMINAL UNITS A SINGLE DUCT TERMINAL UNITS • 3000 SERIES Performance Data • Hot Water Coil Models: 30RW, 30RWQ and 30HQW Unit Sizes 7 and 8. Nailor International Group has representatives in most major cities throughout the world. The units shall be provided with a primary variable air volume damper that controls the air quantity in response to a (thermostat or digital controller/zone sensor). Nailor manufactures a unique and comprehensive line of products essential for a well designed HVAC system. Complete Air Control and Distribution Solutions | Nailor Industries, Inc. Nailor Industries Inc. Nailor manufactures its own electric heating coils. Nailor Industries Inc. VAV Features Option: Unique Duct Final Units Once that fabrication cooling/heating load has been calculated and the VAV system has been laid out, the view tread your used the. Nailor Single Duct Exhaust Terminal Units are used to modulate exhaust flow from an occupied space in either a constant volume or variable air volume (VAV) HVAC system. The equipment used in those days to air condition commercial office buildings was high velocity, dual duct systems—and bypass multizoneVAV System Design Considerations. 00. INSTALLATION • All single duct terminal units with electric coils are designed to be mounted in a horizontal plane. These. Electronic VAV Retrofit Kit. Incorporation of an airflow sensor allows the SDV to compensate instantly for any change in supply air pressure that might alter the supply volume resulting in a pressure independent variable air volume system. Imitated but Never Duplicated Building engineers, owners, and occupants can rest easy knowing their Nailor Fan Powered Terminal Units provide the best combination of sound, control, and comfort. 4 - 17 - 20 VAV-FF TERMINAL UNITS LINER OPTIONS SOUND POWER LEVEL CORRECTION FACTORS TYPE: FIBER-FREE INSULATION. The terminal unit will respond to the space thermostat to increase/decrease the airflow to maintain the set point. Nailor Solutions. reserves the right to change any information concerning product or pricing without notice. 4. T3LN. Nailor Industries Inc. One of the decisions when designing a VAV system is what type of terminal units to use in the system. The PCV uses either a field calibrated electric or PIC DDC controller to ensure that over or under pressurization of the duct will not occur. DATE B SERIES SUPERSEDES DRAWING NO. The flow sensor measures aforementioned total. Hahn Mason Air Systems are experts in the design and application of. reserves the right to change any information concerning product or pricing without notice. Nailor Industries Inc. . Units shall be manufactured by Nailor Industries Inc. density Steri-Liner insulation. There are a lot of differences between Nailor and other fan powered VAV terminal unit manufacturers. The units shall be provided with a primary variable air volume damper that controls the air quantity in. 2 For more information visit | v100 SD. 84 per cfm per year versus damper leakage @ $0. SINGLE DUCT TERMINAL UNITS A SINGLE DUCT TERMINAL UNITS • 3000 SERIES Performance Data • Hot Water Coil Models: 30RW, 30RWQ and 30HQW Unit Size 12 2 Row (multi-circuit) 10 7. reserves the right to change any information concerning product or pricing without notice. The previous version addressed only variable air volume (VAV) air-handling systems and. • Damper – Heavy gauge steel AHUs in VAV systems are controlled using Trim and Respond control logic. Nailor 35N and 37N Fan Powered Terminal Units offer a compact and economical design that provides excellent performance in the most demanding variable air volume/intermittent fan applications. galvanized steel with round or flat oval inlets. Coupled with a wide range of. , The Ohio State University Chair of Advisory Committee: Dr. F4 BYPASS TERMINAL UNITS F BYPASS TERMINAL UNITS Unique "Flow Diverter" Valve Nailor's 3400 Series Mark II bypass terminal units utilize a. Nailor Industries Inc. These. Page 1 of 4 Receiving Inspection After unpacking the assembly check it for shipping damage. Fan powered variable air volume terminals are a popular choice for heating and cooling. DATE B SERIES SUPERSEDES DRAWING NO. The largest size that Nailor offers is the 33SZ-55, it can handle up to 2,000 CFM. Terminal units inclusive a flow transducer, controller/actuator, and damper to measure and control airflow. My cart 0 item(s) - $ 0. COOLING WITH HOT WATER REHEAT • DIRECT ACTING, NORMALLY OPEN • VARIABLE AIR VOLUME • PRESSURE. • Digital VAV Terminal Units Catalog • July 24, 2018 (Supersedes: July 10, 2018 ) Author: Nailor Subject: Terminal Units Catalog Created Date: 7/24/2018 1:38:46 PM. SINGLE DUCT VAV TERMINAL UNIT COOLIN G/HEATING WITH AUTO CHANGEOVER PRESSURE INDEPENDENT MODEL: 3001 N101 Nailor Industries Inc. reserves the right to change any information concerning product or pricing without notice. The portfolio. PERFORMANCE DATA SDV – Recommended Air Volume Ranges Digital Controls Unit Size cfm Min. The laboratory obtained discharge and radiated sound power levels in octave bands 2 through 7 (125 through 4000 Hz) center frequency for each unit size at various flow rates and inlet static. DATE B SERIES SUPERSEDES DRAWING NO. 5 - 17 - 22 VAV. Single Duct Terminal Unit. Series units contain a fan that is operational at the same time as the air handling unit. In a standard environment the 35SST could have a similar NC as the 35SXC. Dimensions are in inches (mm). Catalogs are. The diffuser is manufactured from corrosion-resistant steel. 00 260 Days per Year 12 Hrs per DayNailor Industries Inc. Nailor Subject: VAV Terminal Units - Liner Options - Type: Steri-LinerSINGLE DUCT TERMINAL UNIT PNEUMATIC CONTROLS • PRESSURE INDEPENDENT VARIABLE OR CONSTANT VOLUME MODEL: P3001 Dimensional Data Unit Size Airflow Range* cfm (l/s) W H Inlet Size 4 5 6. Reps Area Engineers Area. Model D30HQX - Single Duct Exhaust Terminal Unit Author: Nailor Subject:. 9. Units shall reset to any flow between 0 and the maximum cataloged airflow as allowed by the specific controller. volume single duct terminal units. Constant Volume Pneumatic High Mixing Dual Duct Terminal. pressure independent variable air volume system. Retrofit - 3600. 2. • Digital VAV Terminal Units Catalog • September 23, 2021 (Supersedes: April 8, 2021) Author: NailorNailor Industries Inc. The fan is mounted at ninety degrees to the primary airflow to provide optimum mixing. VAV Terminal Units, Green Building products, Fan Coil. Fan Powered Terminal Units • 33SZ, 35N, 35S, 37N and 37S Series • All sizes. 3 - 12 - 18 3000 10 - 28 - 16 D30HQ Page 1 of 1. VAV (35N, 37N) CAD model selection Filter settings. Nailor Subject: Terminal Units Fiber-Free Liner Options Sound Power Level Correction FactorsVariTrane® Single Duct Terminal Units. reserves the right to change any information concerning product or pricing without notice. MOA303 - Multi-Outlet • 3 Foot Long. NC Levels are calculated based on procedures as outlined on page B75. 1 - 12 - 21 VAV-SL TERMINAL UNITS LINER OPTIONS SOUND POWER LEVEL CORRECTION FACTORS TYPE: STERI-LINER. One of the decisions when designing a VAV system is what type of terminal units to use in the system. FAN POWERED TERMINAL UNITS C. The NFD-VAV core design3000 SERIES. Nailor manufactures a unique and comprehensive line of products essential for a well designed HVAC system. 3/15 IOM-SDTU Page 1 of 4 Nailor Industries Inc. Page 1 of 2 Model Series: 3000 Single Duct 3210 Dual Duct 35S-OAI Series Fan Powered w/ O. Nailor Industries Inc. The core design produces a low velocity helical "swirl" discharge air pattern. This includes the load on the space, the static pressure in the ductwork, the types of terminal units, and the occupancies in the space. • Digital VAV Terminal Units Catalog • November 1, 2022 (Supersedes: October 4, 2022 ) Author: Nailor Subject: Terminal Units Catalog Created Date: 11/24/2022 8:39:06 AM. plated steel drive shaft. SCHEDULE TPE: PROECT: ENINEER: CONTRACTOR: FAN POWERED TERMINAL UNIT WITH EPIC ECM MOTOR SERIES FLOW • CONSTANT OR VARIABLE VOLUME MODELS: 35S, 35SW AND 35SE • UNIT SIZES 1 – 6 DATE B. Nailor• VAV section is lined with 13/16" (21), thick, 4 lb. duct from the terminal unit. Chilled Water Fan Powered - 33S. VAV Terminal Units:. 1. , FEL/FE EER ASHRAE; PEN SOLOMO , PH. Pneumatic Dual Duct. com 36VRS • Retrofit Terminal Units • Square or Rectangular • Pressure Independent 36VRTR • Retrofit Terminal Unit • Round • Trane • Digital Controls 36VZR • Retrofit Terminal Units • Static Pressure Control • Round Duct, Bypass or Branch Nailor 3000 Series Single Duct Terminal units are simply put, versatile. 11 - 19 - 12 VAV. All terminals with electric heat have been tested and ETL listed as an assembly, eliminating the need to mount coils a minimum of 36" (914) downstream or having to ship a bulky length of ductwork when coils are to be supplied mounted on the terminal. Wireless Link For LonWorks, BACnet, Modbus & Ethernet Iinstallations. The PCV uses either a field calibrated electric or PIC DDC controller to ensure that over or under pressurization of the duct will not occur. SINGLE DUCT VAV TERMINAL UNIT MODEL: 30RW CONTROL SEQUENCE: 1P3 (CSC-3011) Nailor Industries Inc. The first letter in the model number indicates control type (P is for pneumatic). Apply filter Remove filter Cancel. This includes the load on the space, the static pressure in the ductwork, the types of terminal units, and the occupancies in the space. AT305 - 5 Foot Long. (750 Pa). , operating under Nailor International Group is a privately held, family owned company with Group headquarters located in Houston, TX. 4 45 400 5 60 500 6 65 550 7 95 800 8 125 1100 9 160 1400 10 210 1800Throttling VAV Terminal Units •Damper inlet controls supply air between a min/max flow ratea min/max flow rate •Includes a reheat coil and control valve. Nailor Industries, Inc. Dimensions are in inches (mm). galvanized steel with round or flat oval inlets. The Nailor product catalog is the ultimate industry resource for information. Nailor Industries Inc. He is a former chair of TC 5. Finishes. TRANE ® ROUND RETROFIT TERMINAL UNIT DIGITAL OR ANALOG ELECTRONIC CONTROL PRESSURE INDEPENDENT •VAV •EXTERNAL MODEL: D36VRTR Nailor Industries Inc. Nailor 3400 Series Bypass Terminal Units are designed to provide variable air volume supply when used with constant volume fan low pressure packaged air handling systems or roof-top air conditioning units. reserves the right to change any information concerning product or pricing without notice. SUPERSEDES DRAWING NO. The fan powered options were energy savers for buildings from the very. Perry Fiberglass Products, Inc. Accessories. With unit heights between 15 1/4” and 20 1/8”, and airflow ranges between 100 and 2400 CFM, the FDC-DOAS proves to be an excellent. PMDV. TM UT TALLAT TAT DT 2 TM UT TALLAT TAT DT Manual priceindustriesco PRODUCT OVERVIEW Fan Powered Constant Volume Units – FDC-1-X, FDC-G2SINGLE DUCT VAV TERMINAL UNIT MODEL: 30RW CONTROL SEQUENCE: 3P3 (CSC-3011) Nailor Industries Inc. Nailor manufactures a range of standard and custom design retrofit terminal units for all applications. Downstream Static Pressure. PEDC. VAV Terminal Units, Green Building products, Fan Coil. The terminal unit will respond to the space thermostat to increase/decrease the airflow to maintain the set point. reserves the right to change any information concerning product or specification without notice or obligation. model 35S. Figure 1: Support Using Hanger Straps (Shown: Model D30RW - Single Duct VAV Terminal Unit with Hot Water Heat). Contact your local Nailor Representative for more information on how to order the complete Nailor catalog library. D. The diffuser has a factory mounted controller, sensor and actuator. reserves the right to change any information concerning product or specification without notice or obligation. Nailor 3600 Row Retrofit Terminal Units can designed for all applications and are engineered to transform inept constant volume systems to presence day variable air volume systems with low setting costs. The cost of leakage in VAV equipment has been calculated to be $1. DATE B SERIES SUPERSEDES DRAWING NO. Of course, this was not solely due to the terminal units, but they were definitely instrumental to the system. Though operating independently, the UNI2-VAV and terminal unit controlsSINGLE DUCT TERMINAL UNITS A SINGLE DUCT TERMINAL UNITS • 3000 SERIES Performance Data • NC Level Application Guide 3000 Series • Basic Unit Fiberglass Liner Inlet. Available in 15 individual valve sizes to up to 15,000 cfm. Nailor Industries Inc. The central air handling unit (AHU) of a VAV system is designed to deliver ventilation and recirculated cooled air to the terminal units. notes: 1. • Slip and drive cleat duct connection on both ends. Contact Hahn-Mason Air Systems today at (704)-523-5000. SelectWorks files are exportable and easily. 13. reserves the right to change any information concerning product or. If the design included VAV diffusers in every office, maintaining constant pressure in the supply duct downstream of the terminal unit. Variable air volume (VAV) / Constant Volume boxes are great energy savers by delivering the exact amount of heated or cooled air to the conditioned space. BYPASS TERMINAL UNITS F BYPASS TERMINAL UNITS Unique "Flow Diverter" Valve Nailor's 3400 Series Mark II bypass terminal units utilize a unique cylindrical flow diverter valve for superior control and performance. A non-programmable thermostat is required on master units and controls up to 20 different diffusers. The Price FDC-DOAS series fan powered terminal unit with a sensible cooling coil is an excellent solution for imparting large sensible loads on the zone when a Dedicated Outdoor Air System is utilized. Model 36VRR Model 36VRS Model 36VR E RETROFIT TERMINAL UNITS an ASHRAE paper in 1989 claiming that this combination of fan powered terminal units and VAV air handlers was saving about 20% of the building energy at that time. A mechanical engineer must consider several variables and equipment types when designing a VAV system. Nailor 3000 and 3100 Series Terminal Units are among the most versatile VAV boxes on the market, providing easy HVAC system integration with diverse control packages. Shallow plenums are common where zoning requirements limit building height. • Convert Constant Volume Dual Duct Systems to Variable Air Volume • Convert Multizone Systems to Variable Air Volume • Convert Mechanical Constant Volume Regulators to Low Pressure Pneumatic, Analog Electronic or Digital Controls. The VAV diffuser enables the control of airflow into a room with a connected thermostat. Parallel Fan Powered Units. parallel designed VAV terminal units when the internal fan was turned off. D-Fan_Powered-VAV-2013_D-Fan_Powered-2005VAV-bwnew 6/25/13 3:15 PM Page D127 Title Nailor Industries Inc. When compared to a single duct terminal unit, the fan-powered versions have a fan that enables the induction of plenum air into the airflow. Diffusers. AT35SW - 3’ Long • for Models 35S and 35SST. Dan Int-Hout is chief engineer at Krueger in. The terminal unit only responds to the conditions in the office with the thermostat. VAV Terminal Units-Nailor. Nailor 3400 Series Bypass Terminal Units are designed to provide. Model 3210 is used when no terminal mixing is required. Advanced micro-computer electronics and P+control algorithmsΙ provide precise temperature control. Literature. In 1971, Michael T. The 33SZ Series Fan Powered Chilled Water Terminals enhance Nailor’s already efficient and flexible Series Fan Terminal Unit. Nailor offers three models of dual duct terminal units to meet a variety of applications. The recently released 2021 version of ASHRAE Guideline 36 includes 24 addenda developed over the last three years. Model 36VRR Model 36VRS Model 36VR E RETROFIT TERMINAL UNITSan ASHRAE paper in 1989 claiming that this combination of fan powered terminal units and VAV air handlers was saving about 20% of the building energy at that time. Nailor 3000 also 3100 Series Terminal Units are among the most versatile VAV mail on the market, making easy HVAC system integration with diverse control packaged. “We are a market leader in the HVAC industry. Corporation in the ARI 880 Certification program. Dual Duct units have had a renewed interest of late due to the concern for IAQ requirements and how best to meet a buildings IAQ requirements. Single Duct Terminal Units Nailor Industries Inc. Nailor 3000 plus 3100 Series Single Duct VAV Depot Units key a cool and versatile build that results in a system component which has minimal pressure drop that reduces fan horsepower demand, and low noise generation for quiet operation. AT35NE - 3’ Long • for Model 35NE. Fan Powered Terminal Units • 33SZ, 35N, 35S, 37N and 37S Series • All sizes. Damper 38S UnderfloorFan Powered Inlet Duct Area K-Factor Velocity F-Factor BYPASS TERMINAL UNITS 3400 SERIES MARK II • "DUMP BOX" • UNIQUE "FLOW DIVERTER" VALVE Model 3400 BYPASS TERMINAL UNITS F BYPASS TERMINAL UNITS FEATURES: • Casing – 22 ga. c. When terminal blending of cold and hot decks is required, both the model 3230 and 3240 are excellent. 4. 11 - 2 - 22 3000 10 - 6 - 21 D3001-1 Page 2 of 2. Designed for. Nailor Industries Inc. reserves the right to change any information concerning product or specification without notice or obligation. Nailor manufactures a unique and comprehensive line of products essential for a well designed HVAC system. E. • All electric heating units have built-in controls for all options required by the engineer. The Price FDC, series flow, fan powered terminal unit, is designed to supply air volume to the occupied zone in response to a control signal. SINGLE DUCT TERMINAL UNIT WITH DISSIPATIVE SILENCER HOSPITAL GRADE • SUPER QUIET. Nailor Superior Features and Efficiencies – Fan Powered VAV Terminal Units There are a lot of differences between Nailor and other fan powered VAV terminal. Chilled Water terminal units and chilled beams each have their features and benefits for delivering comfort. In this scenario, if all three VAV diffusers were wide open each office would supply 100 CFM. Allows units to be quickly installed or relocated. 5 in. with hot water reheat or electric heat . Nailor 3600 Series Retrofit Terminal Units are designed for all applications and are engineered to transform inefficient constant volume systems to present day variable air volume systems with low installation costs. Nailor Industries Inc. ONE smallish footprint makes these units simple to use and install in today‘s cramped mechanical spaces and. A minimum shaft length of 2. Multipoint crossflow sensor for accurate flow measurement. VAV Controls. The diffusers are extruded aluminum and available in either a one or two-way pattern. Leading The Industry. 38. Single Duct Terminal Unit with Factory Mounted Valve Package. A3400 E10 • Analog Electronic Controls • Control Sequence • VAV • Cooling with Time. A Solid metal liner completely isolates the standard insulation and its raw edges from the. Chilled Beams. V2080 - Controls Enclosure. D-Fan_Powered-VAV-2013_D-Fan_Powered-2005VAV-bwnew 6/25/13 3:15 PM Page D127 Title Nailor Industries Inc. is known for our industry leading customer focused approach to providing innovative commercial and industrial HVAC products. Variable air volume (VAV) / Constant Volume boxes are great energy savers by delivering the exact amount of heated or cooled air to the conditioned space. • Digital VAV Terminal Units Catalog • July 24, 2018 (Supersedes: July 10, 2018 ) Author: Nailor35N, 35NW, 35NE • Fan Powered Terminal Units • PSC Motor • Size 2 - 6. •Rectangular inlet and discharge with slip and drive cleat duct connection. Designed for cooling only, cooling with reheat, heating only or heat/cool changeover applications. Units shall be pressure independent with. less than 2% of the terminal rated airflow at 3"w. Nailor Industries, Inc. Upgraded components, current control systems and building design improvements helped to increase the use of fan-powered VAV termi-nal units. • Same liner as terminal unit. SelectWorks is a simple, yet effective tool designed to aid the user in selecting and scheduling Nailor's VAV Terminal Units, Fan Powered Terminal Units, and Fan Coil Units. SINGLE DUCT VAV TERMINAL UNIT COOLING WITH FLOATING REHEAT PRESSURE INDEPENDENT MODEL: 30RW N103 Nailor Industries Inc. Turning the manual fan speed control counterclockwise will increase the fan speed; clockwise will decrease speed. They are common in premium VAV systems and in applications such as conference rooms, cafeterias, etc. The Nailor UNI VAV diffuser enables the control of airflow into a place with a connect thermostat. CONTROL SEQUENCE 1P3 • VAV COOLING WITH PROPORTIONAL HOT WATER HEAT •. They have been specifically designed and tested for use with variable air volume single duct terminal units. Started in 1971, Nailor Industries Inc. Nailor's 30X and 30HQX Series Single Duct Exhaust Terminal Units are used to modulate exhaust flow from an occupied space in either a constant volume or variable air volume. ; Page 2 – affixed to the. Model 3001 • Basic Unit. FCU . Terminal Units; Underfloor (UFAD) Displacement Diffusers; Electric Duct Heaters; Silencers; Fan Coil Units;. 5 - 12 - 22 VAV. No heater should be applied to exceed this temperature. SINGLE DUCT TERMINAL UNITS A SINGLE DUCT TERMINAL UNITS • 3000 SERIES Performance Data • Hot Water Coil Models: 30RW, 30RWQ and 30HQW Unit Size 14 2 Row (multi-circuit) 10 7. Each unit size is available to suit various duct sizes as shown in the table. Our Terminal Units are built to provide very low pressure drop and sound levels which are certified by ARI. . Fire/Smoke Dampers. Nailor is proud to provide the latest generation of fan powered terminal units-designed to lead the industry. Nailor Industries Inc. • Convert Constant Volume Dual Duct Systems to Variable Air Volume • Convert Multizone Systems to Variable Air Volume • Convert Mechanical Constant Volume Regulators to Low Pressure Pneumatic, Analog Electronic or Digital Controls. 4 - 17 - 20 VAV-FF TERMINAL UNITS LINER OPTIONS SOUND POWER LEVEL CORRECTION FACTORS TYPE: FIBER-FREE. The Price Pressure Control Valve (PCV) is designed as a pressure control valve to regulate duct pressure in a Pressure Independent or Pressure Dependent system. reserves the right to change any information concerning product or pricing without notice. Carnes variable air volume terminal units accurately regulate airflow for maximum occupant comfort. Nailor 37S and 37SST Low Profile Terminal Units are designed for shallow ceiling plenum applications and therefore limited to 11" (279) in height. Register. B7 SINGLE DUCT TERMINAL UNITS B SINGLE DUCT TERMINAL UNITS The recommended airflow ranges below are for terminal units with pressure independent controls and are based. The Price Pressure Control Valve (PCV) is designed as a pressure control valve to regulate duct pressure in a Pressure Independent or Pressure Dependent system. The Nailor NLD floor diffuser is designed to provide VAV control in heating only applications. DUAL DUCT TERMINAL UNITS • 3200 SERIES DUAL DUCT TERMINAL UNITS B B3 MODELS: 3210, 3230 AND 3240 Nailor dual duct terminals are designed to precisely regulate and vary the volume of both the cold and hot deck of a dual duct distribution system in response to thermostat demand. • Digital VAV Terminal Units Catalog • July 24, 2018 (Supersedes: July 10, 2018 ) Author: NailorNailor 3000 and 3100 Browse Terminal Units are amidst the most versatile VAV boxes on the market, supplying easy HVAC system integration with diverse control packages. You are here. 36VRS • Retrofit Terminal Units • Square or Rectangular • Pressure Independent 36VRTR • Retrofit Terminal Unit • Round • Trane • Digital Controls 36VZR • Retrofit Terminal Units • Static Pressure Control •. reserves the right to change any information concerning product or pricing without notice. Figure 1: Support Using Hanger Straps (Shown: Model D30RW - Single Duct VAV Terminal Unit with Hot Water Heat). Trane chilled water sensible cooling terminal units are designed for use in systems that operate up to 5" w. New Product: PAC Learn how our new line of portable air cleaners can help you improve air quality in confined spaces. VAV Terminal Units-Nailor Nailor Variable Air Volume Terminal Units Variable air volume (VAV) / Constant Volume boxes are great energy savers by delivering the exact. (3) For 38S series units with primary air inlet damper, set the unit to full cooling. model 35S. Terminal units are used within a Variable Air Volume (VAV) System to control the airflow and temperature delivered to a zone. Our VAV units, or Variable Air Volume systems, are available as a single duct terminal for cooling only or a fan powered terminal for cooling and heating. SINGLE DUCT TERMINAL UNITS A SINGLE DUCT TERMINAL UNITS • 3000 SERIES. Nailor started Nailor Industries, Inc. Nailor 35S, 37S, 35SST, 37SST and 35SXC Series Fan Powered Boxes are available in cooling only, electric. Nailor Industries Inc. • Digital VAV Terminal Units Catalog • November 1, 2022 (Supersedes: October 4, 2022 ) Author: Nailor Subject: Terminal Units Catalog Created Date: 11/21/2022 4:38:44 PM. maximum and minimum CFM settings on terminal units with pressure independent control options, and unit tagging (or mark). VAV Terminal Units, Green Building products, Fan Coil. PEDC. 00 $100. Where the only chase units are sized using the inlet of the ductwork, a fan powered unit must choose an inlet size as well as a. 1kw increments because we make our own elements. I would like thank Dr. The air handling unit will typically consist of a fan and a cooling coil. Otherwise, replace the terminal with a lower pressure drop terminal and then reduce the inlet pressure. Nailor Subject: Terminal Units Steri-Liner Liner Options Sound Power Level Correction FactorsFAN POWERED TERMINAL UNITS C C131 FAN POWERED TERMINAL UNITS • 37S/37SST SERIES Performance Data • Hot Water Coil Models: 37SW and 37SWST • Low Profile • Series Flow. performance pages in the Nailor VAV Terminal Unit catalog. Model D3000 Single Duct Terminal Unit VAV Models: 3001 Cooling or Heating only 30RW Cooling with Hot Water Re-heat 30RE Cooling with Electric Re-heat. 3 - 12 - 18 3000 7 - 17 - 17 D3001-1 Page 2 of 2. This would increase the pressure in the. Features such as advanced sensor technology, a wide range of product sizes and air flows, low sound levels, increased hot water coil selections, and innovative options establish Price as an. Complete Air Control And Distribution Solutions: Grilles Registers Diffusers VAV Terminal Units Fire Dampers Smoke Dampers Control Dampers Radiation Dampers LouversNailor Single Duct Exhaust Terminal Units are used to modulate exhaust flow from an occupied space in either a constant volume or variable air volume (VAV) HVAC system. reserves the right to change any information concerning product or specification without notice or obligation. DATE B SERIES SUPERSEDES DRAWING NO. The simplified version of this decision is Series Units for all zones or Parallel units on the exterior and single-duct for interior zones. • Digital VAV Terminal Units Catalog • July 24, 2018 (Supersedes: July 10, 2018 ) Author: NailorOverview. In the parallel fan-powered terminal, the fan section is outside of the primary airstream and typically only runs in the heating mode. Single Duct Terminal Units Nailor Industries Inc. UNITED STATES | CANADA | INTERNATIONAL. The UNI2-VAV is a variable volume diffuser that regulates the amount of supply air into the space. Nailor Industries. today commercial building variable air volume A terminal units. 2. For heat options; see page 2. Nailor Industries Inc. 86) zinc coated steel constructed to provide low leakage. PEFM 4FSJFT 445 4UFBMUI Super Quiet, Series Flow (Constant Volume). reserves the right to change any information concerning product or pricing without notice. Page 3 of 3 Dimensions are in inches (mm). Nailor Industries Inc. Supplied with balancing tees. Unit E, 4427-72nd Avenue S. DATE B SERIES. document: vav-htg rev1 . In cases where there is a concern that the ventilation air will freeze the coil during winter, the AHU will have a heating coil. VAV Terminal Units.